- CHEMICAL DANGERS:
- Ricin
is stable under ambient conditions.
- When
heated to decomposition, ricin emits toxic nitrogen oxides.
-
EXPLOSION HAZARDS:
- Not
established/determined
-
FIRE FIGHTING INFORMATION:
- Ricin
is combustible.
- Ricin
is not volatile, but it may be spread by efforts to extinguish the
fire.
- Avoid
generating dust.
- Use
foam, dry chemical powder, BCF (where regulations permit), carbon
dioxide, water spray, or fog (large fires only).
- If
the situation allows, control and properly dispose of run-off
(effluent).
-
INITIAL ISOLATION AND PROTECTIVE
ACTION DISTANCES:
- If
a tank, rail car, or tank truck is involved in a fire, isolate it for
0.5 mi (800 m) in all directions; also, consider initial evacuation for
0.5 mi (800 m) in all directions.
- This
agent is not included in the DOT ERG 2004 Table of Initial Isolation
and Protective Action Distances.
- In
the DOT ERG 2004 orange-bordered section of the guidebook, there are
public safety recommendations on how to immediately isolate a ricin
(Guide 153) spill or leak area for at least 150 ft (50 m) for liquids
and 75 ft (25 m) for solids in all directions.
- PHYSICAL DANGERS:
- Not
established/determined
- NFPA 704 Signal:
- Health: 4
- Flammability: 1
- Reactivity: 0
- Special:
|
|
- SAMPLING AND ANALYSIS:
- OSHA:
Not established/determined
- NIOSH:
Not established/determined
- ADDITIONAL SAMPLING AND ANALYSIS INFORMATION:
References are provided for the
convenience of the reader and do not imply endorsement by NIOSH.
- AIR MATRIX
Gatto-Menking DL, Hao Y, Bruno JG, Goode MT, Miller M, Zulich AW.
[1995]. Sensitive detection of biotoxoids and bacterial spores using an
immunomagnetic electrochemiluminescence sensor. Biosens Bioelectron
10(6-7):501-507.
O’Brien T, Johnson LH III, Aldrich JL, Allen SG, Liang LT, Plummer AL,
Krak SJ, Boiarski AA [2000]. The development of immunoassays to four
biological threat agents in a bidiffractive grating biosensor. Biosens
Bioelectron 14(10-11):815-828.
Taitt CR, Anderson GP, Lingerfelt BM, Feldstein MJ, Ligler FS [2002].
Nine-analyte detection using an array-based biosensor. Anal Chem
74(23):6114-6120.
- OTHER
No references were identified for this sampling matrix for this agent.
- SOIL MATRIX
Gatto-Menking DL, Hao Y, Bruno JG, Goode MT, Miller M, Zulich AW
[1995]. Sensitive detection of biotoxoids and bacterial spores using an
immunomagnetic electrochemiluminescence sensor. Biosens Bioelectron
10(6-7):501-507.
- SURFACES
Anderson GP, King KD, Gaffney KL, Johnson LH [2000]. Multi-analyte
interrogation using the fibre optic biosensor. Biosens Bioelectron
14(10-11):771-777.
Bayler SA, Rees DA [1982]. Analysis of the proteins, glycoproteins and
glycosaminoglycans of fibroblast adhesions to substratum. Biochim
Biophys Acta (BBA)—Biomembranes 689(2):351-362.
Narang U, Anderson GP, Ligler FS, Burans J [1997]. Fiber optic-based
biosensor for ricin. Biosens Bioelectron12(9-10):937-945.
O’Brien T, Johnson LH III, Aldrich JL, Allen SG, Lian LT, Plummer AL,
Krak SJ, Boiarski AA [2000]. The development of immunoassays to four
biological threat agents in a bidiffractive grating biosensor. Biosens
Bioelectron 14(10-11):815-828.
Smallshaw JE, Firan A, Fulmer JR, Ruback SL, Ghetie V, Vitetta ES
[2002]. A novel recombinant vaccine which protects mice against ricin
intoxication. Vaccine 20:(27-28):3422-3427.
Taitt CR, Anderson GP, Lingerfelt BM, Feldstein MJ, Ligler FS [2002].
Nine-analyte detection using an array-based biosensor. Anal Chem
74(23):6114-6120.
Wadkins RM, Golden JP, Pritsiolas LM, Ligler FS [1998]. Detection of
multiple toxic agents using a planar array immunosensor. Biosens
Bioelectron 13(3-4):407-415.
Wannemacher RW Jr., Hewetson JF, Lemley PV, Poli MA, Dinterman RE,
Thompson WL, Franz DR [1992]. Comparison of detection of ricin in
castor bean extracts by bioassays, immunoassays, and chemical
procedures. Toxicon 30(5-6):562.
Wellner RB, Hewetson JF, Ploi MA [1995]. Ricin–mechanism of action,
detection, and intoxication. J Toxicol-Toxin Rev 14(4):483-522.
Xinglong Y, Lequn Z, Hong J, Haojuan W, Chunyong Y, Shenggeng Z [2001].
Immunosensor based on optical heterodyne phase detection. Sensors
Actuators B: Chem 76(1-3):199-202.
- WATER
Anderson GP, King KD, Gaffney KL, Johnson LH [2000]. Multi-analyte
interrogation using the fibre optic biosensor. Biosens Bioelectron
14(10-11):771-777.
Carter RM, Jacobs MB, Lubrano GJ, Guilbault GG [1995]. Piezoelectric
detection of ricin and affinity-purified goat anti-ricin antibody. Anal
Lett 28(8):1379-1386.
Darby SM, Miller ML, Allen RO [2001]. Forensic determination of ricin
and the alkaloid marker ricinine from castor bean extracts. J Forensic
Sciences 46(5):1033-1042.
Delehanty JB, Ligler FS [2002]. A microarray immunoassay for
simultaneous detection of proteins and bacteria. Anal Chem
74(21):5681-5687.
Despeyroux D, Walker N, Perace M, Fisher M, McDonnell M, Bailey SC, Griffiths
GD, Watts P [2000]. Characterization of ricin heterogeneity by
electrospray mass spectrometry, capillary electrophoresis and resonant
mirror. Anal Biochem 279(1):23-36.
Gatto-Menking DL, Hao Y, Bruno JG, Goode MT, Miller M, Zulich AW.
[1995]. Sensitive detection of biotoxoids and bacterial spores using an
immunomagnetic electrochemiluminescence sensor. Biosens Bioelectron
10(6-7):501-507.
Griffiths GD, Newman H, Gee DJ [1986]. Identification and
quantification of ricin toxin in animal tissues using ELISA. J Forensic
Sci Soc 26(5):349-358.
Hines HB, Brueggemann EE [1994]. Factors affecting the capillary
electrophoresis of ricin, a toxic glycoprotein. J Chromatogr A
670(1-2):199-208.
Koja N, Shibata T, Mochida K [1980]. Emzyme-linked immunoassay of ricin.
Toxicon 18(5-6):611-618.
Mi JQ, Gao J, Li YZ, Chang WB, Ci YX [2001]. Ricin determination by
temperature controlled phase-separation immunoassay. Anal Lett
34(7):1143-1151.
Narang U, Anderson GP, Ligler FS, Burans J [1997]. Fiber optic-based
biosensor for ricin. Biosens Bioelectron 12(9-10):937-945.
Poli MA, Rivera VR, Hewetson JF, Merrill GA [1994]. Detection of ricin
by colorimetric and chemiluminescence ELISA. Toxicon 32(11):1371-1377.
Puu G [2001]. An approach for analysis of protein toxins based on thin
films of lipid mixtures in an optical biosensor. Anal Chem 73(1):72-79.
Shyu HF, Chiao DJ, Liu HW, Tang SS [2002]. Monoclonal antibody-based
enzyme immunoassay for detection of ricin. Hybridoma and Hybridomics
21(1):69-73.
Taitt CR, Anderson GP, Lingerfelt BM, Feldstein MJ, Ligler FS [2002].
Nine-analyte detection using an array-based biosensor. Anal Chem
74(23):6114-6120.
Yu H, Raymonda JW, McMahon TM, Campagnari AA [2000]. Detection of
biological threat agents by immunomagnetic microsphere-based
solid-phase fluorogenic and electrochemiluminescence. Biosens
Bioelectron 14(10-11):829-840.
|